Tower Bolts – 2, A Review of Assumptions by Kotur Raghavan
General
In an earlier article, a
simulation model for structural assessment of tower bolts was discussed (https://www.fembestpractices.com/2020/10/design-analysis-of-tower-bolts-by-kotur.html
). The model was developed by invoking certain simplifying assumptions. The
most important simplification was elimination of the frame and the socket from
the analysis model. As a result, the bolt was considered to be an integral
extension of the door and was constrained at the set screw locations. One of
the concerns from the computed results was negative reactions at some of the constraint
locations. This article is for a review of the model from this point of view.
Approach
A slightly different bolt
configuration, as shown in the Fig. 1, is presently considered.
Fig. 1
Six possible constraint locations
nodes 1 to 6 and nodes 11 to 16 are identified as shown. Two different analyses
are carried out. In the first case, constraints are applied at nodes 1 to 6. In
the second case all twelve nodes are constrained. In both the cases load is
applied in the region L as shown.
For Case 1 analysis, the reaction
forces are given below.
Fig. 2
The figure gives reaction forces
corresponding to the constrained nodes 1 to 6. It is to be noted here that
algebraically negative reaction forces are positive reactions in a physical
sense. Nodes 5 and 6, which are in line with the applied load, both show
positive reactions. At the other two locations, the constrained nodes nearer to
the load are reacting positively. The pattern indicates that both the top and
bottom bolts are ‘locally’ bending about the horizontal axis.
For Case 2, the reaction forces
are given below.
Fig. 3
As compared to Case 1, there are
two notable aspects here.
1. The
central bolt nodes 15 and 16, which are farther away from the load application
point, are experiencing negative reactions. At top and bottom, all the additional
constrained nodes are also showing negative reactions. The implication is that
the central bolt is bending locally about the vertical axis. The other two
bolts are bending locally about some oblique axes.
2. More
importantly, the magnitude of reaction forces at 5 and 6 and also 2 and 3 are
all higher in Case 2.
Discussion
1. The
observed reaction patterns and magnitudes are understandable and are valid from
mechanics point of view.
2. However,
from a structural design point of view the implication is that deployment of
additional screws happen to be counter-productive.
3. The
above statement does not make engineering sense. Hence we look for possible
lacunae in the simulation model.
4. We
recall here that the displacement constraint are applied at the set screw
locations. Constraints allow reactions of either sense. In the present problem,
positive reactions indicate tension in the screw and negative reactions
correspond to compression.
5. Whereas
the screws can resist tensile load coming on to them they cannot resist
compressive forces. Compressive forces in the door-bolt-frame assembly go
directly to the frame.
6. Thus
there obviously a shortcoming in the simulation model. It is an unrealistically
oversimplified model.
Compression in screws will reduce the pre load. Only after the complete loss that the load will be transferred to the frame. When we apply constrain in a simulated FE model we implicitly assume that all the fixing points are simultaneously coming into action. This may not be practically tenable. I still feel redundancy issue should be addressed.
ReplyDeleteThe screws are not actually getting compressed. There is no way of inducing compression in the screw. For that matter in any bolted joint the bolt will always be in tension. I will develop a real model and share.
ReplyDeleteHello! Great article and thank You for Providing Such a Unique and valuable information on The Manifold Pipe Solution Inc. for your readers. I really appreciate it. You can also visit Buy grade 8.8 bolts for more Manifold Pipe Solution Inc. related information and knowledge.
ReplyDeleteHi there to everyone, the contents present at this web page are actually amazing for people knowledge, well, you can also visit Inconel 625 Bolts for more Jignesh Steel related information and knowledge. Keep up the good work.
ReplyDeleteHi to every single one, it’s truly a good for me to visit this web page, I love your content, they are very nice and it includes helpful Information. Check out our website stainless steel flanges manufacturers in india for more Great Steel & Metals related info! I am truly pleased to read this website posts which carries lots of helpful data, thanks for providing these kinds of statistics.
ReplyDeletefirst off, a hearty thanks to you. Your blog is awesome and completely knowledgeable and I completely satisfied with the reading. Keep your work spread till long after. For more API 5L ERW Pipe manufacturers in India related information visit rexaltubes.Certainly, you are Right!!
ReplyDeleteI wanted to thank you for this great Information and knowledge, I definitely loved every little bit of it. I have you bookmarked your web site to check out the latest stuff you post. Your blog is eye-catching. I get pleasure from it. Thanks for sharing this beautiful piece of writing with me, get more information at Alloy Steel Pipe suppliers in India for more ashtapad related information and knowledge.
ReplyDelete